Energies, Vol. 18, Pages 5274: Heat Pipe Heating and Cooling Building Modules: Thermal Properties and Possibilities of Their Use in Polish Climatic Conditions

Energies, Vol. 18, Pages 5274: Heat Pipe Heating and Cooling Building Modules: Thermal Properties and Possibilities of Their Use in Polish Climatic Conditions

Energies doi: 10.3390/en18195274

Authors:
Karolina Durczak
Bernard Zawada

The subject of this paper is an analysis of the use of wall heating and cooling modules with heat pipes for efficient space heating and cooling. The modules under consideration constitute a structural element installed in the room’s partition structure and consist of heat pipes embedded in a several-centimeter layer of concrete. Water-based central heating and chilled water systems were used as the heat and cooling source. The heat pipes are filled with a thermodynamic medium that changes state in repeated gas–liquid cycles. The advantage of this solution is the use of heat pipes as a heating and cooling element built into the wall, instead of a traditional water system. This solution offers many operational benefits, such as reduced costs for pumping the heat medium. This paper presents an analysis of the potential of using heat pipe modules for heating and cooling in real-world buildings in Poland. Taking into account the structural characteristics of the rooms under consideration (i.e., internal wall area, window area), an analysis was conducted to determine the potential use of the modules for space heating and cooling. The analysis was based on rooms where, according to the authors, the largest possible use of internal and external wall surfaces is possible, such as hotels and schools. Based on the simulations and calculations, it can be concluded that the modules can be effectively used in Poland as a real heating and cooling element: standalone, covering the entire heating and cooling demand of a room, e.g., a hotel room, or as a component working with an additional system, e.g., air cooling and heating in school buildings. The changes in outdoor air temperature, during the year analyzed in the article, were in the range of −24/+32 °C.

More From Author

Energies, Vol. 18, Pages 5273: Modelling, Simulation and Performance Analysis of Floating Photovoltaic Systems—A Systematic Review and Meta-Analysis

Energies, Vol. 18, Pages 5272: A Direct-Drive Rotary Actuator Based on Modular FSPM Topology for Large-Inertia Payload Transfer

Leave a Reply

Your email address will not be published. Required fields are marked *