Energies, Vol. 18, Pages 6272: Assessment of Overall and Module-Specific Performance Comparisons for Residential Grid-Tied Photovoltaic Systems in the Maldives

Energies, Vol. 18, Pages 6272: Assessment of Overall and Module-Specific Performance Comparisons for Residential Grid-Tied Photovoltaic Systems in the Maldives

Energies doi: 10.3390/en18236272

Authors:
Khalid Adil Ali Mohamed
Hussain Shareef
Ibrahim Nizam
Ayodele Benjamin Esan
Ahmad K. ALAhmad

Global restrictions related to climate change and the increasing demand for electricity are accelerating the transition from conventional energy sources, such as oil, gas, and coal, to renewable options like wind, solar, and biomass. Among these, solar photovoltaic (PV) systems are highly promising, offering clean and reliable electricity generation. In support of the Maldives’ target to achieve net-zero emissions by 2030, the deployment of PV systems has significantly increased. However, there is still a lack of detailed operational performance assessment specific to the Maldives. This study aims to address this gap and fulfill three main objectives. Firstly, to evaluate the real performance of six selected rooftop grid-connected PV systems installed in the Greater Malé region, Maldives. Secondly, the ideal performance ignoring shading, soiling, and aging effects of the selected systems on the islands are simulated, and the optimal orientation angles are estimated. Finally, the real and predicted performances are compared, and a module-level analysis is conducted to pinpoint the area for improving the performance of the rooftop PV systems installed on the island. The well-known International Electro-Technical Commission (IEC) standard, IEC 61724, is used for operational performance assessment, in addition, the PVsyst simulation tool and the S-Miles microinverters monitoring system are implemented for simulation and module-level analysis, respectively. In 2023, the six studied sites recorded annual daily averages of 2.52–4.45 kWh/kWp/day for yield factor, 0.98–2.9 h/day for total loss, 45.19–82.13% for performance ratio (PR), 10.51–18.55% for capacity utilization factor (CUF), and 7.69–15.94% for system efficiency. The actual performance was found to be lower than the simulated ideal values. The main reasons for this reduction were near-shading and microinverter connection issues. The orientation study showed that a 5° tilt angle with an azimuth between −25° and 5° gives the best results for fixed PV installations. These findings can guide better PV system design and operation in the Maldives and other similar climates.

More From Author

Energies, Vol. 18, Pages 6273: Quantitative Modeling of Fluid Phase Evolution in Ordovician Reservoirs of the Shuntuoguole Area, Tarim Basin: Implications for Oil and Gas Phase Differentiation

Energies, Vol. 18, Pages 6271: A Novel Dynamic Ampacity Assessment Method for Direct Burial Cables Based on an Electro-Thermal-Fluid Multiphysics Coupling Model

Leave a Reply

Your email address will not be published. Required fields are marked *