Helium News

Global Helium Industry Intelligence

Energies, Vol. 19, Pages 1511: Field Tests and Applicability Analysis of an Underground Cooling Installation Powered by Ventilation Air Methane (VAM)

Energies, Vol. 19, Pages 1511: Field Tests and Applicability Analysis of an Underground Cooling Installation Powered by Ventilation Air Methane (VAM)

Energies doi: 10.3390/en19061511

Authors:
Robert Hildebrandt
Marcin Smołka
Wodzisław Piekarczyk
Krzysztof Skrzypkowski

Modern underground hard coal mines encounter increasing natural hazards as mining depth increases, including, in particular, significant rises in both methane and thermal hazards. Thermal threats are common in Polish mines, especially in areas where the primary rock temperature exceeds 40 °C. To provide an energy source for cooling systems and reduce methane emissions from ventilation air, a system based on a catalytic reactor combined with an absorption chiller was developed. Field tests conducted at the experimental mine Barbara in Mikołów (Poland) indicate that a COP based on methane chemical energy can reach a level of 0.3–0.4. An application analysis was conducted based on the results of cross-sectional forecasts of climatic conditions (thermal conditions forecasts). The results indicate the potential for using this installation as a supporting component of mine cooling systems. An important factor that may limit the efficiency of the installation is the volume flow of the exhaust air stream. It is estimated that, in countries where, as in Poland, air temperature is the primary criterion for assessing thermal safety, the results of the analysis would be similar.